P0200 INJECTOR CRCUIT ERROR

AutoHex Online Help: Hyundai VERACRUZ/ix55(EN) 2011
Component Location
General Description

ECM controls injection amount and injection timing through Electrical control injector in order to control system pressure which is required for measuring and injection of diesel fuel. Injectors on CRDi injects atomized fuel with highly pressurized directly into the combustion chamber corresponding to fuel amount ECM decided. Fuel injected into combustion chamber generates power through the explosion.

There are 2 different fuel injection on the S engine. One is 2 time pilot injection for reducing explosion noise during fuel control, another is main injection for generating power. In addition, those are controlled independently by ECM and injection time (injection amount) as well. Injector is newly adopted new technology. that are hydraulic coupler which transfer operating force of actuator as quickly as possible and PIEZO actuator what is operating response better than solenoid actuator. Both PIEZO actuator and hydraulic coupler realized to increase the fuel pressure to 250 ~ 1600bar. That makes high combustion efficiency resulting to reduced smog and improved engine power and fuel efficiency.



DTC Description

DTC P0200 is set when more than one of the injectors is short to battery or ground among 6 injectors. If this code is retrieved, check all the injectors whether injectors circuit are short to battery / ground in circuit.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

? Current Monitoring

? Injector circuit

? Injector component

Enable Conditions

? IG key ON

Threshold Value

More than one of injectors are

? Short to battery in circuit.

? Short to ground in circuit.

Diagnostic Time

? Immediately

Fail Safe

Fuel cut

YES

? MIL is blinking when no inputting IQA.

EGR Off

NO

Fuel Limit

NO

Check Lamp

ON

Specification

Control Type

Component Resistance

Operating Voltage

PIEZO voltage control

150 ~250 kO (20?)

100V ~ 200V (100V ~ 140V at 250bar)

Diagnostic Circuit