4 shift solenoid valves are installed directly in valve-body. The solenoids operates of ON and OFF by the control signal from TCU.
Combinations of 4 solenoids, S1, S2, S3 and S4, changes gear ranges(1st to 6th)
TCM set this code If detected "ON(12V)" signal When TCM output "OFF(0V)" signal to "Shift control solenoi valve D(S4)"
Item
Detecting Condition
Possible Cause
DTC Strategy
Open/short
Wiring harness(S4) short to Battery or OPen
Shift control solenoi valve D(S4)
TCM
Enable Conditions
10.2V < Battery voltage < 14V
Not error in system
CAN communication : normal
S4 drive output "OFF" signal
Threshold Value
To detected "ON" signal (12V) of the S4 monitor, When S4 drive output "OFF" signal (0V)
Diagnostic Time
More than 0.5 second.
Fail Safe
Fixed at 4th gear.
Measuring Position
Resistance (20?)
Signal - Ground
11 ~ 16 ?
Fig 1) D Range-1st gear
Fig 2) D Range-2nd gear
Fig 3) Sports mode -1st gear
Fig 4) Sports mode -2nd gear
Fig 5) Sports mode -3rd gear
Fig 6) Sports mode -4th gear
Fig 7) Sports mode -5th gear
Fig 8) Sports mode -6th gear
Fig 9) Reverse