Follow us on Twitter and win Autohex II Scan Tool for Kia and Hyundai (worth 945.00 USD)

U0105 Lost Communication With Fuel Injector Control Module

AutoHex Online Help: Hyundai GENESIS(BH) 2012
General Description

Several control units are applied to electronically controlled vehicles. These units perform each control with informations from various sensors. Thus, sharing signal information from sensors is needed, so CAN communication type whose communication speed is high and insensitive to electrical noise by spark generation is adopted to controlling power-train(ECM, IDB,ESP ECM, ABS ECM) As sharing signals of engine speed, APS, gear shifting, torque reduction in ESP and various modules, active control is performed.

DTC Description

Checking CAN communication, under detecting condition, if an CAN communication error between ECM and IDB is detected . ECM sets U0105.



DTC Detecting Condition

Item

Detecting Condition

Possible cause

DTC Strategy

CAN communication with IDB status check

IDB faulty

CAN communication line between ECM and IDB

EnableConditions

B+ > 10.8V

Time after Ignition switch on = 0.5 sec

Threshold value

Duration of communication lost with IDB > 4 sec

Diagnosis Time

Continuous

MIL On Condition

2 driving cycle

Specification

Communication Format

DIGITAL "0"

DIGITAL "1"( BUS IDLE )

CAN Communication

Line Resistance

HIGH

LOW

HIGH

LOW

ECM

Cluster

CAN 2.0B

3.5V

1.5V

2.5V

2.5V

120? (20?)

120? (20?)

Diagnostic Circuit Diagram
Signal Waveform & Data

Fig.1) Can communication waveform at idle

Monitoring CAN HIGH and LOW simultaneously is important in monitoring CAN communication waveform. When CAN HIGH signal rise to 3.5V and LOW signal drops to 1.5V - voltage difference between HIGH and LOW signal is 2V - at BUS IDLE state(DIGITAL "1") whose reference voltage is 2.5V, "0" is recognized. Besides, comparing HIGH and LOW signal if opposite waveform is detected with the reference voltage of 2.5V, Check if current cam signal transfers correctly.

Continuous "0"signal above 6BIT means the occurence of error in CAN communication. 1BIT is easily distinguished as calculating the time when "SOF"(START OF FRAME) which notifies the start of frame occurs. Check if "0"signal above 6BIT is detected continuously when monitoring CAN communication waveform.