The PCM provides a 5volt reference voltage to the Air-con Pressure Transducer(APT) and Power Steering Pressure Sensor(PSPS). The PCM monitors reference voltage deviation from the power supply circuit of the APT and PSPS.
PCM sets DTC P06A5 if the PCM detects reference voltage of APT is Higher than threshold value.
Item
Detecting Condition
Possible Cause
DTC Strategy
Electrical Check
Short to battery in power circuit
Poor connection or damaged harness
Faulty APT
Enable Conditions
IG "ON"
Threshold Value
Short to battery
APT >5.5V
Diagnostic Time
0.1sec.
MIL On Condition
1 Drive Cycle