Follow us on Twitter and win Autohex II Scan Tool for Kia and Hyundai (worth 945.00 USD)

P0136 O2 Sensor Circuit(Bank 1 / Sensor 2)

AutoHex Online Help: Hyundai VELOSTER(FS) 2012
Component Location
General Description

HO2S(S2) is in the rear side of Catalytic Converter to check the proper operation of catalyst. Oxygen density after the catalytic converter has to be within specific range (around 0.5V when there is no acceclation and deceleration.)

If the oxygen density changes in accordance with HO2S(S1), it means the poor performance of catalytic converter.



DTC Description

In case the sensor output is 0.4~0.52 V during 600sec or the internal resistance is over 40 ? under enable conditions, ECM sets DTC P0136.( This DTC might be caused by the malfunction of Heater circuit, so, check the heater circuit first. )

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Signal check

Poor connection

Open or short in signal circuit

S2

General

Enable

Conditions

Dew point end detected

Battery voltage > 11V

Exhaust Gas temperature = 350?~800?

No upstream O2 sensor heater error

Case1

ThresholdValue

Sensor voltage : 0.4~0.52 V

DiagnosticTime

600 sec

Case2

ThresholdValue

Rate of heater pulse coupling to sensor signal > 5 times per every 10 heating pulses

MIL ON Condition

3 driving cycle

? S2 : upstream oxygen sensor / S2 : downstream oxygen sensor

Diagnostic Circuit Diagram
Signal Waveform and Data

If you release the accelerator pedal suddenly after engine running about 4000 rpm, fuel supply will stop for short period and the O2 sensor service data in the Hi-Scan (Pro) will display values 200mV or lower. When you suddenly press on the accelerator pedal down, the voltage will reach 0.6 ~ 1.0 V. When you let the engine idle again, the voltage will fluctuate between 200 mV or lower and 0.6 ~ 1.0 V. In this case, the O2sensor can be determined as good.